Certified performance
Every row is a door brought into the lab
The tables below come from the General Catalogue and apply to the Plastic Laminate Collection. The code is the one used to order the door; next to it is the construction that makes that number possible—the thickness of the leaf, the movable threshold, the type of hinge—because the performance is not just the leaf on its own; it is part of the whole. If a certificate is available, it can be downloaded here.
Soundproofed · timber frame
Sound insulation with wooden frame, Plastic Laminate Collection
| Code | Sound insulation | Leaf thickness | Automatic drop seal | Hinges | Document |
|---|
| 193I30 | 30 dB | 44 mm | Light | 4 Anuba | certificate |
| 193I33 | 33 dB | 46 mm | Decibel | Concealed | certificate |
| 193I37 | 37 dB | 44 mm | Decibel | Concealed | certificate |
| 193I38 | 38 dB | 56 mm | Decibel | Concealed | certificate |
| 193I39 | 39 dB | 44 mm | Decibel | Concealed | certificate |
| 193I47 | 47 dB | 70 mm | Light + Decibel | Concealed | certificate |
Soundproofed · aluminium frame
Sound insulation with aluminum frame, Plastic Laminate Collection
| Code | Sound insulation | Leaf thickness | Automatic drop seal | Hinges | Document |
|---|
| 193I28 | 28 dB | 44 mm | Decibel | Concealed | certificate |
| 193I31 | 31 dB | 54 mm | Decibel | Concealed | certificate |
| 193I36 | 36 dB | 44 mm | Decibel | Concealed | certificate |
Sound insulation tests are performed at an accredited laboratory in accordance with UNI CEI EN ISO/IEC 17025, with the measurement method UNI EN ISO 10140-2 and evaluation according to UNI EN ISO 717-1.
Air Permeability · frame Aluminum
Air permeability with frame aluminum
| Code | Type | Permeability | Leaf thickness | Automatic drop seal | Hinges |
| 193E | Hinged or sliding, 1 leaf | Class C | 44 mm | Decibel | Concealed |
| 193E31DBALL | 1 hinged leaf | Class C | 46 mm | Decibel | Concealed |
| 193E36DBALL | 1 hinged leaf | Class C | 44 mm | Decibel | Concealed |
Fire resistance · wooden frame
Fire resistance with wooden frame
| Code | Fire resistance | Sound insulation | Leaf thickness |
| 193EI45I33 | EI 45 | 33 dB | 44 mm |
| 193EI45I38 | EI 45 | 38 dB | 56 mm |
| to be confirmed | EI 60 | 33 dB | 44 mm |
| 193EI60I38 | EI 60 | 38 dB | 56 mm |
The four doors share the same construction: intumescent seals for hot smoke, plus acoustic seals, on three sides of the frame, self-closing concealed hinges, and thermo-active retaining pins in galvanised steel — two on the lock side, three on the hinge side. The code 163FF adds to the fire-resistance certifications the Sa for cold smoke.
One line in the fire-resistant table is no longer listed in the catalogue but has the same part number as the EI 45 line: the performance is confirmed; we will verify the part number when the order is placed. Fire resistance and air permeability certificates are not published on this page and must be requested via email.
Other acoustic certifications on file
They refer to other collections, not to the plastic laminate in the tables above.